HVAC Glossary — Plain-English Definitions
The HVAC vocabulary you'll hear when getting a quote or reading a service report. Bookmark this.
Tools & ReferencesJanuary 15, 20268 min read
Every trade has jargon. Here's the plain-English translation for the HVAC terms you'll hear from contractors, on service reports, and in equipment marketing.
Efficiency ratings
- SEER / SEER2
- Seasonal Energy Efficiency Ratio (v2). Cooling efficiency over a season, higher = more efficient. Federal minimum in Southwest region: 14.3 SEER2 for split AC. See What Is SEER2?
- EER / EER2
- Energy Efficiency Ratio at a single hot design point (95°+). More relevant than SEER2 in the Coachella Valley — we spend hundreds of hours above 110°F. Look for EER2 ≥ 12 for Valley applications.
- HSPF / HSPF2
- Heating Seasonal Performance Factor (v2). Heat-pump heating efficiency over a season. Matters more at higher elevations than on the Valley floor.
- AFUE
- Annual Fuel Utilization Efficiency. Gas furnace efficiency percentage. 80% AFUE = 80% of the fuel becomes useful heat; the rest goes up the flue. 96% AFUE is "condensing" — captures much more heat but requires PVC venting.
- COP
- Coefficient of Performance. Heat pump heat output ÷ electrical input. COP 3 = 3× the heat output per unit of electricity. Higher outdoor temperature = higher COP for heat pumps in heating mode.
Sizing and load
- BTU / BTU/hr
- British Thermal Unit. Heat measurement. HVAC capacity is measured in BTU/hr. 1 ton of cooling = 12,000 BTU/hr.
- Ton
- HVAC capacity unit. Comes from the era of ice-based cooling: 1 ton = the cooling delivered by melting 1 ton of ice per day. Coachella Valley homes are commonly 2.5–5 tons.
Refrigeration cycle
- Compressor
- The heart of the system. Compresses refrigerant to increase temperature/pressure. Failure = major repair or replacement decision.
- Evaporator coil
- Indoor coil where refrigerant absorbs heat from house air. Also called the "A-coil" or "cased coil."
- Condenser coil
- Outdoor coil where refrigerant releases heat to outside air. What you see when you look at the outdoor unit.
- Refrigerant / R-410A / R-454B / R-32
- The working fluid. R-410A was the standard 2010–2024; R-454B and R-32 are the lower-GWP replacements as of 2025+. See R-454B vs R-410A.
- TXV (thermostatic expansion valve)
- Meters refrigerant into the evaporator coil based on load. Common failure item on older systems.
- Superheat / Subcool
- Diagnostic numbers that reveal whether refrigerant charge is correct. Set at commissioning; measured at every tune-up.
Airflow and ductwork
- CFM
- Cubic Feet per Minute. Airflow measurement. Standard target: ~400 CFM per ton of cooling.
- Static pressure
- Air pressure across the air handler, measured in inches of water column ("WC). High static = restricted airflow (dirty filter, undersized duct, closed dampers). Should be under 0.5" WC total across the air handler.
- Plenum
- The large duct box directly on the air handler. Supply plenum distributes conditioned air; return plenum brings return air back.
- MERV
- Minimum Efficiency Reporting Value. Filter rating from 1 (loose) to 20 (HEPA-adjacent). See Air Filters & MERV.
Controls
- Contactor
- Relay that switches 240V power to the compressor and outdoor fan when the thermostat calls for cooling. Common failure item, cheap to replace.
- Capacitor
- Component that stores the jolt required to start the compressor and outdoor fan. Fails more in high heat. Most common single failed part in Valley systems.
- Float switch (drain safety)
- Cuts thermostat power when the condensate drain pan fills. Prevents attic water damage. Trips = clogged drain.
- Reversing valve
- Heat-pump-specific component that switches the refrigerant flow direction to change between cooling and heating.
Regulatory / installation
- AHRI Certified
- Air-Conditioning, Heating & Refrigeration Institute certificate confirming a specific outdoor + indoor combination has been tested as a matched system. Required for warranty and most rebates.
- Title 24
- California's building energy code. HVAC installs must comply; some require HERS field verification.
- HERS Verification
- Home Energy Rating System field verification by an independent third party — confirms duct sealing, refrigerant charge, and airflow meet code. Required on many California HVAC installs.
Terms that mostly don't matter
- "Two-stage compressor" — real feature but marketed heavily. Modest benefit in the Valley.
- "Variable-speed" — real feature. Worth the money in some applications, overkill in others.
- "iSEER" / "Super Efficient" — marketing terms. Not standardized. Ask for actual SEER2 / EER2 / HSPF2.
Missing a term? Tell us and we'll add it.